Shannon Sheridan (poundbotany63)
Taken together, the proposed RIM method has potential application in large-scale quantitative study of complex samples.Exposure to styrene is a major safety concern in the fibreglass processing industry. This compound is classified by the International Agency for Research on Cancer as a possible human carcinogen. Several types of analytical equipment exist for detecting volatile organic compounds (VOCs) in the atmosphere; however, most of them operate ex-situ or do not provide easy discrimination between different molecules. This work introduces an improved and portable method based on FTIR spectroscopy to analyse toxic gaseous substances in working sites down to a concentration of less than 4 ppm. Styrene and a combination of VOCs typically associated with it in industrial processes, such as acetone, ethanol, xylene and isopropanol, have been used to calibrate and test the methodology. selleck products The results demonstrate that the technique offers the possibility to discriminate between different gaseous compounds in the atmosphere with a high degree of confidence and obtain very accurate quantitative information on their concentration, down to the ppm level, even when different VOCs are present in a mixture.The presence of potentially toxic xenobiotics in complex matrices has become rather the rule than the exception. Therefore, there is a need for highly sensitive inexpensive techniques for analyzing environmental and food matrices for toxicants. Enzymes are selectively sensitive to various toxic compounds, and, thus, they can be used as the basis for detection of contaminants in complex matrices. There are, however, a number of difficulties associated with the analysis of complex matrices using enzyme assays, including the necessity to take into account properties and effects of the natural components of the test media for accurate interpretation of results. The present study describes the six-stage procedure for designing new enzyme sensors intended for assessing the quality of complex matrices. This procedure should be followed both to achieve the highest possible sensitivity of the biosensor to potentially toxic substances and to minimize the effect of the uncontaminated components of complex mixtures on the activity of the biosensor. The proposed strategy has been tested in designing a bioluminescent biosensor for integrated rapid assessment of the safety of fruits and vegetables. The biosensor is based on the coupled enzyme system NAD(P)HFMN-oxidoreductase and luciferase as the biorecognition element. The study describes methods and techniques for attaining the desired result in each stage. The proposed six-stage procedure for designing bioluminescent enzyme biosensors can be used to design the enzymatic biosensors based on other enzymes.A fluorescent probe was developed for ratiometric detection of thallium ions in mineral water samples by modifying a G-rich aptamer (PS2.M - 7) with a fluorescence donor (Cyanine-3, Cy3) and a quencher (Cyanine-5, Cy5). The probe had a random coil structure that changed into a G-quadruplex structure upon binding with Tl+. This change in structure decreased the distance between the donor and acceptor moieties, which resulted in fluorescence resonance energy transfer between Cy3 and Cy5. Under optimized conditions, the limit of detection and linear concentration range for Tl+ were 30.1 μM (3σ) and 10 μM-10 mM (R2 = 0.9981), respectively. This simple and cost-effective fluorescence sensor provided satisfactory results for detection of thallium ions in spiked mineral water samples.An online separation and preconcentration method, using an automated flow injection setup and solid phase extraction followed by ICP-MS/MS, was developed for the analysis of 90Sr, and U, Am and Pu isotopes in various liquid sample matrices. The radionuclide analytes were separated from interferences and complex matrices using DGA-branched resin and Sr resin, then specific gases were used in the reaction/