Prosthetic joint infection (PJI) is a devastating complication. Studies have suggested reduction in PJI with the use of ceramic bearings. Adult patients who underwent total hip arthroplasty (THA) using an uncemented acetabular component with ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), or metal-on-polyethylene (MoP) bearing surfaces between 2002 and 2016 were extracted from the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. A competing risk regression model to investigate predictors of each revision outcome was used. Time-to-event was determined by duration of implantation since primary surgery with competing risks being death or revision. The results were adjusted for age, gender, American Association of Anaesthesiologists grade, body mass index, surgical indication, intraoperative complications, and implant data. In total, 456,457 THAs (228,786 MoP, 128,403 CoC, and 99,268 CoP) were identified. Multivariable modeling showed that the risk of revision for o MoP. Significant reduction in risk of aseptic and all-cause revision was also seen. The significant protective effect of ceramic bearing was predominantly seen 2 years after implantation. Aseptic revision beyond 2 years reduced by 18.1% and 24.8% for CoC and CoP (P less then .001), respectively. JAK inhibitor All-cause revision rate beyond 2 years reduced by 21.6% for CoC and 27.1% for CoP (P less then .001) CONCLUSION This study demonstrates an association between the use of ceramic as part of the bearing, with lower rates of revision for all causes, revision for infection, and revision for aseptic causes, supporting ceramic bearings in THA.This study evaluated safety and image quality of MRI exams performed for patients with traumatic knee dislocations in knee-spanning stabilization devices. It is an IRB-approved retrospective design with waived informed consent that included 63 patients with traumatic knee dislocation. 56 patients had metallic external fixators, and 7 patients had non-metallic knee immobilizers. 7 patients had bilateral dislocations yielding a total of 70 knee MRIs. 1.5 Tesla MRI exams were performed for all patients who were awake and alert at the time of imaging. All knee-spanning external fixators were considered "MR conditional" by the FDA. The electronic medical record was reviewed for notes from the technologist and nursing staff documenting any patient complaints or adverse events during the MRI exam as required by departmental protocol. Qualitative analysis of the six most frequently performed sequences were independently conducted by 2 musculoskeletal radiologists using a 5-point Likert scale. Overall image quality and select time intervals between the two groups were compared using an independent sample t test and the Mann-Whitney U test, respectively. No adverse events were reported for a 40-minute average estimated patient scan time with the stabilization devices in the MR gantry. Mean values of Likert scale scores were generated from two readers' data for comparison between the external fixation and the immobilizer groups. Most knee MRI exams with external fixators were within diagnostic quality despite artifacts (grade 3). MRI exams generally were of higher diagnostic quality in the immobilizer group than the external fixator group (p less then 0.05). The external fixator models included DePuy Synthes, Smith and Nephew, Stryker Hoffman III, Zimmer FastFrame, and Zimmer XtraFix. MRI examinations in patients with external fixators for traumatic knee dislocations can be safely performed under certain conditions and provide diagnostic quality images.Developmental dysplasia of the hip (DDH) metrics based on 3-D ultrasound have proven more reliable than those based on 2-D images, but to date have been based mainly on hand-engineered features. Here, we test the performance of 3-D convolutional neural networks for automatically segmenting and delineating the key anatomical