Gregory Thisted (genderwood25)

BACKGROUND Accurate diagnosis of symptomatic low von Willebrand factor (VWF) remains a major challenge in von Willebrand disease (VWD). However, present tests do not adequately take into account flow forces that, at very high shear rates, reveal a weakness in the VWF-platelet glycoprotein glycoprotein Ib bond in normal subjects. The degree of this weakness is greater in symptomatic, but not asymptomatic, low VWF. OBJECTIVE The aim of this study is to distinguish patients with symptomatic low VWF (levels in the 30-50 IU/dL range) from those with asymptomatic low VWF and normal subjects. METHODS We measured platelet adhesion (PA)/aggregation in our novel microfluidic flow system that permits real-time assessment of PA (surface coverage) and PA/aggregation (V, aggregate volume) using epifluorescence digital videomicroscopy in flowing noncitrated whole blood at 4,000 second-1. Blood samples from 24 low VWF patients and 15 normal subjects were collected into plastic tubes containing 4 U/mL enoxaparin. MetaMorph software was used to quantify rates of PA and V increase. RESULTS Rates of PA increase showed a bimodal distribution, with values for 16/24 patients (Group I) all below the 2.5th percentile of normal, and values for 8/24 patients (Group II) similar to controls. Bleeding scores (mean ± standard error) were 5.50 ± 0.45 versus 2.75 ± 0.45 (p = 0.00077), and 10 clinically significant bleeding events were observed in seven versus zero (p = 0.0295) Group I and Group II subjects, respectively. CONCLUSION The present approach may offer a definitive means to distinguish symptomatic low VWF from either asymptomatic low VWF or normal controls. Georg Thieme Verlag KG Stuttgart · New York.BACKGROUND Implantable cardiovascular therapeutic devices, while hemodynamically effective, remain limited by thrombosis. A driver of device-associated thrombosis is shear-mediated platelet activation (SMPA). Underlying mechanisms of SMPA, as well as useful biomarkers able to detect and discriminate mechanical versus biochemical platelet activation, are poorly defined. We hypothesized that SMPA induces a differing pattern of biomarkers compared with biochemical agonists. METHODS Gel-filtered human platelets were subjected to mechanical activation via either uniform constant or dynamic shear; or to biochemical activation by adenosine diphosphate (ADP), thrombin receptor-activating peptide 6 (TRAP-6), thrombin, collagen, epinephrine, or arachidonic acid. Markers of platelet activation (P-selectin, integrin αIIbβ3 activation) and apoptosis (mitochondrial membrane potential, caspase 3 activation, and phosphatidylserine externalization [PSE]) were examined using flow cytometry. Platelet procoagulant activity wass via circulation through a ventricular assist device-propelled circulatory loop. CONCLUSION Elevated shear stress, but not biochemical agonists, induces a differing pattern of platelet biomarkers-with enhanced PSE and thrombin generation on the platelet surface. This differential biomarker phenotype of SMPA offers the potential for early detection and discrimination from that mediated by biochemical agonists. Georg Thieme Verlag KG Stuttgart · New York.BACKGROUND Cardiovascular events are associated with low circulating vitamin D concentrations, although the underlying mechanisms are poorly understood. This study investigated associations between 25-hydroxyvitamin D concentrations, platelet function, and single-nucleotide polymorphisms (SNPs) in genes influencing vitamin D biology in the 500 Functional Genomics (500FG) cohort. METHODS In this observational study, platelet activation and function were measured by flow cytometry by binding of fibrinogen to the activated fibrinogen receptor integrin αIIbβ3 and expression of P-selectin, markers of platelet aggregation and degranulation, respectively. These parameters were correlated to serum 25-hydroxyvitamin D and genotyping was performed to investigate SNPs in genes important for vitamin D