Eliasen Busch (garliccork7)
a decreasing prevalence over time. <br> <br> The discontinuities after the transition from ICD-9 to ICD-10 coding were relatively small for most comorbidities. Medical complications generally showed a decreasing trend over the quarters studied. These findings support caution when conducting joint replacement studies that rely on ICD coding and include the ICD coding transition period. <br>The discontinuities after the transition from ICD-9 to ICD-10 coding were relatively small for most comorbidities. Medical complications generally showed a decreasing trend over the quarters studied. These findings support caution when conducting joint replacement studies that rely on ICD coding and include the ICD coding transition period. <br> For cup revision after total hip arthroplasty, sufficiently good periacetabular bone stock is a prerequisite for fixation of the revision implant. Cementless cups can lead to a relevant reduction of peri-implant bone mineral density (BMD) through stress-shielding. <br> <br> Fifty patients were included in this prospective randomized controlled trial. Group 1 (RM group) received an isoelastic monoblock cup (RM Pressfit vitamys; Mathys). Group 2 (IT group) received a modular titanium cup (Allofit-S IT Alloclassic with a polyethylene liner; Zimmer). Periacetabular BMD was determined and subdivided into 4 regions of interest by dual x-ray absorptiometry at 1 week (baseline) and at 4 years postoperatively. Our primary outcome was reduction in periacetabular BMD. <br> <br> Periacetabular BMD was reduced by an average of 15.1% in the RM group and 16.5% in the IT group at 4 years postoperatively. No significant difference was found between the 2 groups over the periacetabular structure as a whole. Selleck H-Cys(Trt)-OH However, the decrease of BMD in the polar region was significantly different in the RM group (4.9% ± 10.0%) compared with the IT group (15.9% ± 14.9%, p = 0.005). Use of the isoelastic RM cup showed significantly less bone loss than the modular IT cup. <br> <br> Relevant loss of BMD at 4 years after surgery was identified in the periacetabular region in both groups. No differences between the 2 cup systems were found when looking at the overall periacetabular region. As a secondary outcome, less postoperative periacetabular bone loss occurred in the polar region when an isoelastic cup was used. Longer follow-up is required to allow for conclusions to be drawn about the long-term course of the 2 cup systems. <br> <br> Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. <br>Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. <br> Multiple studies comparing nonoperative and operative treatment for displaced proximal humeral fractures in the geriatric population have demonstrated minimal differences in functional outcomes. Factors such as surgeon experience as well as the quality and maintenance of the reduction may influence operative outcomes, and their impact on these findings merits further investigation. <br> <br> In the treatment of 2 and 3-part fractures involving the surgical neck, intramedullary nailing has demonstrated functional outcomes that are comparable with those of open reduction and internal fixation (ORIF). <br> <br> In the geriatric population, reverse total shoulder arthroplasty has demonstrated improved functional outcomes, with a decreased rate of reoperation, compared with hemiarthroplasty. Tuberosity repair has been shown to improve functional outcomes and range of motion after both procedures and should be performed at the time of arthroplasty. <br> <br> Several authors have demonstrated the negative effect of osteopenia on outcomes after ORIF of proximal humeral fractures. Augmentative procedures, including cortical strut augmentation, are being investigated to address this issue; their role in the treatment of these fractures is unclear at this time. <