Rye Hussein (flyleek60)

9, 3.5, and 33 months, respectively. In Ross group, 1 patient required Melody pulmonary valve replacement, whereas none required aortic valve surgery. Finally, significantly higher aortic transvalvular gradient at follow-up was recorded in Ozaki group compared to Ross group. Overall, there was no significant difference in freedom from reoperation or death between the two groups. The medium-term outcome of Ozaki and Ross in pediatric patients is similar, despite an increased tendency of the former to develop aortic transvalvular gradient in the follow-up. Future larger multicenter studies with longer follow-up are warranted to confirm these results.The purpose of this stuy is to prospectively assess the reliability of the ultrasound cardiac output monitor (USCOM™) for measuring stroke volume index and predicting left ventricular outflow tract diameter in adolescents with heart disease. Sixty consecutive adolescents with heart disease attending a tertiary medical center underwent USCOM™ assessment immediately after cardiac magnetic resonance imaging. USCOM™ measured stroke volume index and predicted left ventricular outflow tract diameter were compared to cardiac magnetic resonance imaging-derived values using Bland-Altman analysis. Ten patients with an abnormal left ventricular outflow tract were excluded from the analysis. An adequate USCOM™ signal was obtained in 49/50 patients. Mean stroke volume index was 46.1 ml/m2 by the USCOM™ (range 22-66.9 ml/m2) and 42.9 ml/m2 by cardiac magnetic resonance imaging (range 24.7-59.9 ml/m2). see more The bias (mean difference) was 3.2 ml/m2; precision (± 2SD of differences), 17 ml/m2; and mean percentage error, 38%. The mean (± 2SD) left ventricular outflow tract diameter was 0.445 ± 0.536 cm smaller by the USCOM™ algorithm prediction than by cardiac magnetic resonance imaging. Attempted adjustment of USCOM™ stroke volume index using cardiac magnetic resonance imaging left ventricular outflow tract diameter failed to improve agreement between the two modalities (bias 28.4 ml/m2, precision 44.1 ml/m2, percentage error 77.3%). Our study raises concerns regarding the reliability of USCOM™ for stroke volume index measurement in adolescents with cardiac disease, which did not improve even after adjusting for its inaccurate left ventricular outflow tract diameter prediction.The aim of this study is to assess serum human epididymis protein 4 (HE-4) levels as a biomarker for predicting the recurrence of atrial fibrillation (AF) after catheter ablation. This was a prospective observational study that enrolled one hundred eighty-four consecutive nonvalvular AF patients (65 persistent, 119 paroxysmal) who were eligible for their first ablation. Multiple Cox proportional hazards models and Kaplan-Meier curve analyses were used to test the association between serum HE-4 levels and AF recurrence after catheter ablation. During the 12-month follow-up, we observed that 47 patients (25.5%) experienced AF recurrence. Patients were divided into tertiles of HE-4 level (T1 50 pmol/L) had a significantly increased risk of AF recurrence. In addition, multivariate Cox proportional hazard modelling revealed that HE-4 (≥ 50 pmol/L) (HR 2.65; 95% CI 1.34, 5.27, P = 0.005) was independent predictors of AF recurrence. Serum HE-4 levels in patients with AF are associated with postoperative recurrence of AF, and high HE-4 levels are an independent predictor of AF recurrence after ablation.Transvenous lead extraction (TLE) for cardiac implantable electric device (CIED) infection is becoming increasingly common, but is believed to be particularly risky in elderly patients. This study aimed to clarify the safety and effectiveness of TLE in the elderly, evaluating the use of both non-laser and laser extraction tools. We retrospectively analyzed the characteristics, device type, indications, procedures, and clinical results in younger (YG; age 15-79 years; n = 48) and elderly groups (EG; age ≥ 80 years; n = 27) of pat