Duckworth Stafford (doubtflame5)
nonunion, femoral head necrosis, and other complications. To investigate the occurrence, treatment, and effectiveness of peri-implant refracture after intramedullary nail fixation for intertrochanteric fractures. The clinical data of 16 patients with peri-implant refracture after intramedullary nail fixation for intertrochanteric fractures who met the inclusion criteria between April 2014 and November 2019 were retrospectively analyzed. There were 7 males and 9 females with an average age of 78.4 years (range, 65-93 years). The 14 cases of initial intertrochanteric fractures were classified according to the classification of AO/Orthopaedic Trauma Association (AO/OTA) 5 cases of type A1, 7 cases of type A2, and 2 cases of type A3; the other 2 cases were intertrochanteric combined with subtrochanteric fractures (Seinsheimer type Ⅴ). buy JQ1 According to the classification of peri-implant refracture which was proposed by Chan ., there were 10 cases of type 1 (6 cases of type 1A, 3 cases of type 1B, 1 case of type 1C) and 6 cases of type 2 (4 cases of type 2A and 2 cases fixation for intertrochanteric fractures. Revision with extended intramedullary nail or fixation with limited invasive stabilization system according to the length of initial intramedullary nail and the type of refracture can get satisfactory effectiveness. To evaluate the effectiveness of proximal femoral nail anti-rotation (PFNA) in treatment of high plane intertrochanteric femur fractures. A retrospective analysis was performed on 33 patients who underwent closed reduction and PFNA fixation for high plane intertrochanteric femur fracture between January 2016 and June 2019. There were 12 males and 21 females with an average age of 75.1 years (mean, 47-89 years). The fractures were caused by falling from height in 21 cases, by traffic accident in 7 cases, and by other injuries in 5 cases. Fractures were classified as type A in 14 cases and type B in 19 cases according to self-defined fracture classification criteria; and as type 31-A1.2 in 14 cases and as type 31-A2.2 in 19 cases according to AO/Orthopedic Trauma Association (AO/OTA) classification criteria. The time from injury to operation was 2-5 days (mean, 2.7 days). The operation time, intraoperative blood loss, hospital stay, fracture reduction quality, fracture healing time, internal fixation failurl fixation failure effectively.Biomedical metal materials have always been a major biomedical material with a large and wide range of clinical use due to their excellent properties such as high strength and toughness, fatigue resistance, easy forming, and corrosion resistance. They are also the preferred implant material for hard tissues (bones and teeth that need to withstand higher loads) and interventional stents. And nano-medical metal materials have better corrosion resistance and biocompatibility. This article focuses on the changes and improvements in the properties of several typical medical metal materials surfaces after nanocrystallization, and discusses the current problems and development prospects of nano-medical metal materials. To explore the effects of concentrated growth factor (CGF) combined with mineralized collagen (MC) materials on the adhesion, proliferation, and differentiation of bone marrow mesenchymal stem cells (BMSCs) and their osteogenic effects , and to provide a theoretical basis for the combined application of CGF and MC materials in bone defect regeneration and repair. CGF was prepared from venous blood of healthy volunteers, and then CGF extracts (CGFe) were prepared. experiment human BMSCs (hBMSCs) were divided into 4 groups. Groups A, B, and C were cultured with α-MEM medium [containing 10% fetal bovine serum (FBS) and 1% double antibody] containing 2%, 5%, and 10%CGFe, respectively; group D was cultured with α-MEM medium (containing 10%FBS and 1% double antibody) without CGFe. Scanning electron mi