Drejer Lamont (coincover4)
012) was also associated with a temporal increase in the percentage of patients aged ≧75years. Proportion of patients ≧75years of age for de novo CIED implantation gradually increased from 2006 to 2016, presumably because of the growing number of nonischemic cardiomyopathy and heart failure patients requiring primary prevention of sudden cardiac death. Proportion of patients ≧75 years of age for de novo CIED implantation gradually increased from 2006 to 2016, presumably because of the growing number of nonischemic cardiomyopathy and heart failure patients requiring primary prevention of sudden cardiac death. Patients with cardiac amyloidosis (CA) have increased mortality, which can be explained in part by an increased risk of arrhythmias. The burden of arrhythmias in CA, their predictors, and impact on in-hospital outcomes remains unclear. The role of implantable cardioverter-defibrillators (ICD) in this population is also uncertain. We queried the National Inpatient Sample (NIS) using ICD-9-CM codes 277.39 and 425.7 to identify CA. Twelve common arrhythmias were extracted using appropriate, validated ICD-9-CM codes. ICD implantation was identified using procedure ICD-9 codes 37.94 to 37.98, 00.51 and 00.54. There were a total of 145,920 CA hospitalizations between 1999 and 2014 in the United States and 56,199 (38.5%) of them were associated with arrhythmias. The prevalence of arrhythmias remained relatively constant from 41.5% in 1999 to 40.2% in 2014. The most common arrhythmia was atrial fibrillation (25.4%). In-patient mortality was significantly higher in CA patients with arrhythmias (10.4% vs 6.5%, <.001). ICD implantation was performed in 1,381 (0.94%) patients with CA and analysis revealed an incremental trend in implantation over the study period (0.48% in 1999 to 0.65% in 2014). In-hospital mortality was significantly lower in patients who underwent ICD implantation (3.7% vs 8%; =.0078). CA patients with arrhythmias also had an increased cost of hospitalization and length of stay ($65,046±1,079 vs $53,322±687 and 8.3±0.1 vs 7.4±0.1days, respectively; <.0001). Cardiac arrhythmias are common in patients with CA and are associated with worse in-hospital outcomes, increased length of stay, and cost of hospitalization. Cardiac arrhythmias are common in patients with CA and are associated with worse in-hospital outcomes, increased length of stay, and cost of hospitalization. Three-dimensional (3D) nonfluoroscopic mapping systems (NMSs) are generally used during the catheter ablation (CA) of complex arrhythmias. We evaluated the efficacy, safety, and economic advantages of using NMSs during His-Bundle CA (HB-CA). A total of 124 consecutive patients underwent HB-CA between 2012 and 2019 in our EP Laboratory. We compared two groups 63 patients who underwent HB-CA with fluoroscopy alone from 2012 to 2015 (Group I) and 61 patients who underwent HB-CA with the aid of NMSs from 2016 to 2019 (Group II). Two cost-effectiveness analyses were carried out the alpha value (AV) (ie, a monetary reference value of the units of exposure avoided, expressed as $/man Sievert) and the value of a statistical life (VSL) (ie, the amount of money that a community would be willing to pay to reduce the risk of a person's death owing to exposure to radiation, it is not the cost value of a person's life). The cost reduction estimated by means of both these methods was compared with the real additional cost of using NMSs. The use of NMS resulted in reduced fluoroscopy time in Group II median 1.35min in comparison with Group I median 4.8min ( <.05). The effective dose reduction (ΔE) was 1.16milli-Sievert. The use of NMS significantly reduces fluoroscopy time. However, the actual reduction is modest and in our EP Laboratory this reduction is not cost-effective. Indeed, when the ΔE is referred to country and agenc