Stewart Olesen (breathplant87)

91), and at 2 years postoperatively, the curve was 16° in group A and 17° in group B ( = .75). Over a 2-year follow-up, we did not find significant radiological differences in lumbar curves between patients who underwent surgery before and after menarche. Over a 2-year follow-up, we did not find significant radiological differences in lumbar curves between patients who underwent surgery before and after menarche. Retrospective cohort study. To assess whether the addition of L5-S1 anterior lumbar interbody fusion (ALIF) improves global sagittal alignment and fusion rates in patients undergoing multilevel spinal deformity surgery. Two-year radiographic outcomes, including lumbar lordosis, pelvic incidence, pelvic tilt, and T1 pelvic angle; hardware complications; and nonunion/pseudarthrosis rates were compared between patients who underwent lumbosacral fusion at 4 or more vertebral levels with and without L5-S1 ALIF between November 2003 and September 2016. A total of 51 patients who underwent fusion involving a mean of 11.1 levels with minimum 2-year postoperative radiographic follow-up data were included. Patients who underwent L5-S1 ALIF did not have significant improvement in global sagittal alignment parameters and demonstrated a trend toward a higher rate of nonunion and hardware failure. L5-S1 ALIF did not confer significant benefit in terms of global sagittal alignment and fusion rates in patients undergoing multilevel lumbosacral fusion. Given these results and that L5-S1 ALIF is associated with increased surgical morbidity, surgeons should be judicious in including L5-S1 ALIF in large multilevel constructs. L5-S1 ALIF did not confer significant benefit in terms of global sagittal alignment and fusion rates in patients undergoing multilevel lumbosacral fusion. Given these results and that L5-S1 ALIF is associated with increased surgical morbidity, surgeons should be judicious in including L5-S1 ALIF in large multilevel constructs. Retrospective cohort study. We intend to evaluate the accuracy and safety of cervical pedicle screw (CPS) insertion under O-arm-based 3-dimensional (3D) navigation guidance. This is a retrospective study of patients who underwent CPS insertion under intraoperative O-arm-based 3D navigation during the years 2009 to 2018. The radiological accuracy of CPS placement was evaluated using their intraoperative scans. A total of 297 CPSs were inserted under navigation. According to Gertzbein classification, 229 screws (77.1%) were placed without any pedicle breach (grade 0). Of the screws that did breach the pedicle, 51 screws (17.2%) had a minor breach of less than 2 mm (grade 1), 13 screws (4.4%) had a breach of between 2 and 4 mm (grade 2), and 4 screws (1.3%) had a complete breach of 4 mm or more (grade 3). Six screws were revised intraoperatively. There was no incidence of neurovascular injury in this series of patients. 59 of the 68 breaches (86.8%) were found to perforate laterally, and the remaining 9 (13.2%) medially. It was noted that the C5 cervical level had the highest breach rate of 33.3%. O-arm-based 3D navigation can improve the accuracy and safety of CPS insertion. The overall breach rate in this study was 22.9%. Despite these breaches, there was no incidence of neurovascular injury or need for revision surgery for screw malposition. O-arm-based 3D navigation can improve the accuracy and safety of CPS insertion. The overall breach rate in this study was 22.9%. Despite these breaches, there was no incidence of neurovascular injury or need for revision surgery for screw malposition. Retrospective cohort study. Combined sternal and spinal fractures are rare traumatic injuries and present a high risk of spinal and thoracic wall instability. Limited research has addressed the treatment of sternovertebral injuries and biomechanical n