Kenny Bjerrum (badgergrill08)
Overall, 14.6% of patients presented the composite endpoint ICU and/or death. Neither ALT elevations, prior liver disease, liver stiffness nor liver steatosis (assessed with CAP) had any effect on outcomes. However, patients with abnormal baseline AST had a higher occurrence of the composite ICU/death (21% versus 9.5%, p = 0.002). Patients ⩾65 years and with an AST level > 50 U/ml at admission had a significantly higher risk of ICU and/or death than those with AST ⩽ 50 U/ml (50% versus 13.3%, p less then 0.001). In conclusion, mild liver damage is prevalent in COVID-19 patients, but neither ALT elevation nor liver steatosis influenced hard clinical outcomes. Elevated baseline AST is a strong predictor of hard outcomes, especially in patients ⩾65 years. Although colonoscopy is the gold standard for colorectal cancer screening, colonic looping may make complete colonoscopy challenging. Commonly available stiffening device colonoscopy has been described as helpful but not effective enough to prevent looping. In this context the effect on cecal intubation time and rate was described differently in various studies and in some studies had no impact on cecal intubation time at all. The aim of this study was to evaluate whether a novel colonoscope with gradual stiffness (Fujifilm EC760R-V/I- flexibility adjuster, Tokyo, Japan) using four significantly different grades of stiffness can be an alternative to established devices in terms of loop prevention, cecal intubation rate and time, adverse events, and patient/examiner satisfaction. Consecutive patients without previous colorectal surgery were analyzed retrospectively. see more Colonoscopy was performed with the new colonoscope and performance characteristics, including time to cecum, withdrawal time, total examination time, and patient and endoscopist satisfaction were recorded. Among 180 consecutive procedures, 98.3% of examinations were complete to the cecum. The endoscopic flexibility adjuster was used in 150 of 180 cases (83.3%). Overall, the device was scored by the examiner as helpful to prevent looping in 146 of the 150 cases (97.7%). Mean cecal intubation time was 6.5 min, with 35% of examination performed in under 5 min with a mean withdrawal time of 7 min. Mean total examination time was 18 min. Patient satisfaction was rated as high in all examinations performed. The new flexibility adjuster colonoscope was shown to be helpful in loop prevention, allowed for fast and successful cecal intubation, and led to a high rate of patients satisfaction. The new flexibility adjuster colonoscope was shown to be helpful in loop prevention, allowed for fast and successful cecal intubation, and led to a high rate of patients satisfaction. Gastro-esophageal reflux disease (GERD) is a common disease in gastroenterology outpatients. However, some patients with typical reflux symptoms does not satisfy diagnostic criteria. This study was to explore the value of adjunctive evidence from multichannel intraluminal impedance-pH (MII-pH) monitoring and esophageal high-resolution manometry (HRM) in inconclusive GERD patients with acid exposure time (AET) 4-6%. Endoscopy, MII-pH monitoring and esophageal HRM were retrospectively analyzed from consecutive patients with typical reflux symptoms in a tertiary hospital from 2013 to 2019. Patients were categorized as conclusive or inconclusive GERD according to AET. Adjunctive evidence for GERD diagnosis from Lyon Consensus were collected and analyzed. Among 147 patients with typical reflux symptoms, conclusive GERD was found in only 31.97% of patients ( = 47). The remaining 100 patients (68.03%) were inconclusive GERD, of whom 28% ( = 28) had AET 4-6%. These patients suffered similar reflux burden and impaired esophageal movement. Inconclusive GERD patients with AET 4-6% had lots of positive adjunctive evidence from HRM and MII-pH monitoring. In receiver